š CEREC Troubleshooting Guide
Overview
Sirona CEREC systems are powerful, but certain issues can prevent clean exports, accurate scans, or successful uploads to CAE Dental. This guide lists the most common problems clinicians encounter ā and exactly how to fix them quickly.
ā ļø Common CEREC Issues & How to Fix Them
1. CEREC Wonāt Export STL Files
Symptoms
- āExport failedā
- STL option missing
- Export button grayed out
Causes
- Wrong workflow selected
- Case not finalized
- Software version too old
- Export permissions disabled
Fix
- Complete the entire scan workflow
- Go to Administration ā Export
- Select Model (STL)
- Update CEREC software if STL export is missing
- Restart the software if the export button is frozen
2. Bite Scan Doesnāt Export or Is Missing
Symptoms
- Only upper/lower STL exported
- Bite file not generated
Causes
- Older CEREC versions donāt export bite STLs
- Bite scan not captured correctly
- Bite not finalized
Fix
- Ensure bite scan is captured in the workflow
- If your version doesnāt export bite STLs:
ā Upload upper + lower only
ā CAE Dental will align manually - Update to a newer CEREC version if possible
3. Scan Bodies Not Showing Clearly in the STL
Symptoms
- Scan body looks distorted
- Missing edges or incomplete geometry
- Implant position inaccurate
Causes
- Scan body not fully seated
- Wrong scan body brand
- Shadows or stitching errors
- Scanned too quickly
Fix
- Remove and reseat scan body
- Verify correct brand/model
- Dry the area before scanning
- Capture all surfaces slowly
- Reāscan the implant region if needed
4. Holes or Missing Anatomy in the Scan
Symptoms
- Gaps in the arch
- Missing cusps or margins
- Tissue not captured
Causes
- Fast scanning
- Poor angulation
- Reflective surfaces
- Software stitching errors
Fix
- Reāscan missing areas with slow, steady passes
- Tilt scanner to capture undercuts
- Ensure the field is dry
- Trim excess data and reācapture problem zones
5. Bite Doesnāt Line Up With Upper/Lower Scans
Symptoms
- Occlusion looks off
- Bite appears shifted
- Arches donāt align in STL viewer
Causes
- Patient not fully closed
- Bite captured only on one side
- Distorted bite scan
- Excess saliva or movement
Fix
- Reācapture bite with bilateral contact
- Have patient close in centric relation
- Dry occlusal surfaces
- Capture 3ā5 seconds of stable contact
6. STL Files Wonāt Upload to CAE Dental
Symptoms
- Upload fails
- āUnsupported file typeā
- File too large
Causes
- Wrong file format (e.g., proprietary CEREC format)
- File names contain special characters or PHI
- File size too large
Fix
- Ensure files are .stl
- Rename files to:
Upper.stlLower.stlBite.stl
- Zip large files before uploading
- Remove patient names from filenames
7. CEREC Freezes or Crashes During Export
Symptoms
- Software locks up
- Export window freezes
- CEREC restarts
Causes
- Large case files
- Low system memory
- Software bug
Fix
- Restart CEREC
- Export one file at a time
- Clear old cases from the system
- Update to the latest CEREC version
8. STL Files Look āJaggedā or Low Quality
Symptoms
- Rough surfaces
- Pixelated anatomy
- Poor margin clarity
Causes
- Fast scanning
- Lowāresolution export settings
- Excess saliva or debris
Fix
- Reāscan margins slowly
- Dry the area thoroughly
- Ensure scanner tip is clean
- Update scanner calibration
š§Ŗ Quick Quality Checklist Before Exporting
ā Upper arch complete
ā Lower arch complete
ā Bite captured bilaterally
ā No holes or missing anatomy
ā Scan bodies fully seated (implants)
ā Files named simply (Upper/Lower/Bite)
ā STL exported ā not proprietary format
š Tips for the Best CEREC Results
- Move slowly around margins and scan bodies
- Capture vestibules and palate fully
- Use PLY only if your CEREC version supports it
- Keep scanner tip clean and dry
- Reāscan problem areas instead of relying on stitching
- Always verify STL files in a viewer before uploading